What are the consequences of insufficient torque in Pneumatic Roofbolters?

Mar 11, 2026|

I. Direct impact on drilling efficiency and operational continuity

1. Slow drilling speed and difficulty in advancing footage: Insufficient torque makes it difficult for the drill bit to effectively cut the rock, especially in hard rock conditions (f>8). This manifests as slow rotation speed, difficult advance, and significantly prolonged single-hole operation time.

2. Frequent drill jamming, forcing work interruptions: When encountering well-developed joints or locally hard interlayers, low-torque equipment is prone to drill jamming, requiring repeated retraction and cleaning, severely impacting the construction rhythm.

3. Inability to complete deep hole or large-diameter drilling tasks: Deep hole operations require higher continuous output torque. Insufficient torque will cause drilling to stop midway, preventing the achievement of the designed hole depth.

II. Accelerated equipment wear and shortened service life

1. Overload operation of motor and gearbox: To maintain drilling, operators often "hard-push" the machine by increasing the air supply pressure, causing the motor to operate under overload for extended periods, leading to problems such as gear wear and bearing damage.

2. Increased Wear on Drill Rods and Bits
Insufficient torque easily leads to uneven wear of the drill bit and detachment of the alloy plates. Simultaneously, the drill rod is at risk of bending or breakage due to poor torsion.

3. Increased Burden on the Pneumatic System
The need for continuous high air supply pressure increases the load on the air compressor, potentially causing a chain reaction of failures such as air leaks at pipe joints and pressure reducing valve malfunctions.

III. Threats to Support Quality and Construction Safety

1. Insufficient Anchor Bolt Pre-tightening Force, Support Failure
Insufficient torque directly affects the tightening force during anchor bolt installation, resulting in insufficient anchoring force and significant safety hazards such as roof delamination and roof collapse.

2. Increased Safety Risks for Operators
The moment the drill gets stuck, a violent counter-torque is generated. If the equipment is not controlled stably, it can easily cause operator sprains or injuries from rotating parts. Such accidents must be strictly prevented on-site.

3. Failure to Pass Project Quality Acceptance
If the anchor bolt torque fails the spot check during on-site inspection, rework is required, which not only delays the construction period but may also affect project settlement.

IV. Recommendations: How to Avoid Insufficient Torque

✅ Model Selection and Matching: Select a model with the corresponding torque rating based on the rock hardness (f-value). For example, if f≤10, select the MQT series with a rated torque ≥130 N·m.

✅ Air Supply Guarantee: Ensure the air source pressure is stable at 0.4~0.6 MPa, and the intake pipe diameter is not less than 25 mm to avoid excessive pressure drop.

✅ Regular Maintenance: Check the lubrication status of the oil cups, clean the air filter element, and tighten all connections to maintain efficient operation of the power system.

What details should be considered when cleaning a Pneumatic Top Mount Roofbolter Anchor Drill?

Send Inquiry