What Safety Precautions Should Be Taken When Using The Pneumatic Anchor Cable Releaser?

Jun 16, 2025|

Preparation before operation
1. Check the integrity of the equipment: When replacing the jack tool anchor, screw the tool anchor jacket and the top pressure device to the bottom to prevent damage to the jack parts.
2. Check the oil volume: Check the oil volume in the oil pump to ensure that the hydraulic oil is sufficient.
3. Check the connection between the oil pump and the anchor releaser: Connect the oil pump to the anchor releaser to ensure that the connection is secure.
4. Check the tool anchor clip: The tool anchor clip should be kept clean and have sufficient lubricating oil.
5. Check the site environment: Check the support conditions at the construction site to prevent the collapse and the top from injuring people.
Precautions during operation
1. Exhaust inspection: After the hydraulic oil system is connected, the exhaust step must be carried out. Place the hand pump slightly higher than the jack in use, move the reversing valve, shake the hand pressure rod, extend the piston of the jack, and then move the reversing valve to retract the piston. Repeat this operation several times to exhaust the gas.
2. Operator cooperation: Two people should operate the anchor cable unanchor device, one person is responsible for operating the anchor unanchor jack, and the other is responsible for operating the manual oil pump.
3. Safety distance: It is strictly forbidden to stand within the 45-degree angle below the anchor unanchor device to prevent the jack from falling off and injuring people.
4. Monitoring equipment parameters: During operation, the working pressure of the hydraulic system should be closely monitored to prevent it from exceeding the rated working pressure of the machine.
5. Abnormal sound handling: If there is an abnormal sound during operation, the operation should be stopped immediately for inspection; after confirming that there are no dangerous factors, the operation can be carried out again.
6. It is strictly forbidden to replace the oil pump at will: It is strictly forbidden to replace the oil pump equipped with this equipment at will.
7. Prevent the steel strand from breaking: During work, other equipment such as single hydraulic props should be used to lift the top plate to reduce the pressure of the top plate to assist the machine to withdraw the anchor to prevent the steel strand from breaking and causing the top plate to collapse.
Maintenance after operation
1. Cleaning and maintenance: Clean, remove dirt and wipe clean in time after use.
2. Regular inspection and replacement of hydraulic oil: The machine tools should be inspected regularly and the problematic parts should be repaired or replaced in time.
3. Storage environment: When storing the machine tools, a dry and ventilated environment should be selected to avoid moisture and direct sunlight.
Other precautions
1. Overload operation is prohibited: Operators should strictly prohibit overload operation and must operate in accordance with the load-bearing capacity and instruction manual of the machine tools.
2. Professional operation: Operators should have relevant professional knowledge and skills, and non-professionals are strictly prohibited from operating.
3. Stay calm: During the operation, you should stay calm, abide by the operating procedures, and do not modify the machine tools or perform non-standard operations at will.
4. Communication and coordination: When encountering any problems or difficulties, you should communicate with relevant personnel in a timely manner to jointly seek solutions.

Pneumatic Gear Pump Type Anchor Cable Releaser