Mailfrank.jin@hiscore-mach.com
Phone+8613812591787
enLanguage
  • 日本語
  • 한국어
  • Français
  • Deutsch
  • Español
  • Italiano
  • Português
  • Việt Nam
  • Türkçe
  • عربي
  • русский
  • 简体中文
  • Čeština
  • ไทย
  • Eesti
  • Gaeilgenah Éireann
  • Bai Miaowen
  • íslenska
  • Cymraeg
  • Български
  • اردو
  • Polski
  • hrvatski
  • українська
  • bosanski
  • فارسی
  • Lietuvių
  • Latviešu
  • עברית
  • România limbi
  • Ελληνικά
  • dansk
  • magyar
  • Norsk
  • suomi
  • Nederlands
  • Svenska
  • slovenčina
  • slovenščina
  • हिंदी
  • Indonesia
  • Melayu
  • Malti
  • Kreyòl Ayisyen
  • Català
  • বাংলা
  • Srbija jezik (latinica)
  • O'zbek
RectangleHiscore Machinery Technology Co., Ltd.
Nav
  • Advanced Search
  • Home
  • Products
    • High-precision Gears
      • Wind Energy Gearbox Gear
      • Rail Vehicle Gearbox Gear
      • Mining Industry Gear
      • Petrochemical Industry Gear
      • Port Lifting Industry Gear
      • Construction Machinery Industry Gear
      • Machining Equipment Gear
    • Coal Mine and Tunneling Applications
      • Pneumatic Roof Bolters
      • Pneumatic Rib Drill
      • Pneumatic Drilling Rig for Water and Gas Prospecting
      • Pneumatic Anchor Cable Tensioning
      • Pneumatic Anchor Cable Releaser
      • Anchor Line Shears
    • Mining Drilling Machinery
    • Pneumatic Component
  • Videos
    • Gear Production
    • Mining Equipment
  • About Us
    • Company Profile
    • Technical Support
    • Our Advantage
  • News
  • Blog
  • Contact Us
  • Article
Search
HISCORE MACHINERY
Home /

Blog

hot knowledges
  • How to quickly replace vulnerable parts of Pneumatic Roofbolters

    How to quickly replace vulnerable parts of Pneumatic Roofbolters

    DateJun 15, 2026
  • How to quickly troubleshoot Pneumatic Roofbolters

    How to quickly troubleshoot Pneumatic Roofbolters

    DateJun 13, 2026
  • Pneumatic Roofbolters Operating Instructions

    Pneumatic Roofbolters Operating Instructions

    DateJun 11, 2026
Contact us
  • phone1+86-13812591787
  • mail2frank.jin@hiscore-mach.com
  • Location1No.69, Yabao Avenue, Jiangyin City, Jiangsu Province, China
  • How to Prevent Pneumatic Roofbolters Malfunctions?
    Date2026-1-09

    How to Prevent Pneumatic Roofbolters Malfunctions?

    I. Pre-Operation Preparation 1. Certification: Operators must be trained and pass an examination before operating the equipment. 2. Environmental Inspection: Ensure the work area is flat, dry, and wel
  • What are some common malfunctions of Pneumatic Roofbolters?
    Date2026-1-07

    What are some common malfunctions of Pneumatic Roofbolters?

    I. Insufficient Motor Power 1. Low air pressure or insufficient air volume: Check if the air supply valve is fully open, if the air supply hose is damaged, if the intake pipe diameter is too small, or
  • How to Use Pneumatic Roofbolters Correctly?
    Date2026-1-05

    How to Use Pneumatic Roofbolters Correctly?

    I. Pre-Operation Preparation Certification: Operators must be trained and pass an examination before operating the machine. Environmental Inspection: Ensure the work area is flat, dry, and well-ventil
  • How to Properly Use and Maintain Pneumatic Roofbolters?
    Date2026-1-02

    How to Properly Use and Maintain Pneumatic Roofbolters?

    I. Pre-Operation Preparation Certified Operator: Operators must be trained and certified. Environmental Inspection: Ensure the work area is flat, dry, and well-ventilated; remove any debris. Component
  • How to properly wear Anchor Line Shears protective gear?
    Date2025-12-31

    How to properly wear Anchor Line Shears protective gear?

    1. Safety glasses: Choose impact-resistant and splash-proof goggles, ensuring the lenses are scratch-free. When wearing, adjust the nose pads and temples to ensure the frames fit snugly against your f
  • What are some common malfunctions of Anchor Line Shears?
    Date2025-12-29

    What are some common malfunctions of Anchor Line Shears?

    1. Hydraulic System Problems: If the equipment fails to start or has insufficient power, check if the hydraulic pump is supplying oil normally and ensure the oil circuit is clear and the oil level is
  • How to Use Anchor Line Shears
    Date2025-12-26

    How to Use Anchor Line Shears

    1. Inspection and Connection: First, inspect the cutter's appearance to ensure it is not loose or damaged. Then, connect it to the hydraulic pump using a high-pressure hose. 2. Air Purging Operati
  • Common Faults of Mining Anchor Cable Removal Devices
    Date2025-12-24

    Common Faults of Mining Anchor Cable Removal Devices

    1. Anchor cup or tool anchor deformation, twisting, or stripping: This is the main cause of anchor cables getting stuck and unable to be removed. If the anchor cup has not undergone high-frequency que
  • Does the Pneumatic Anchor Cable Releaser need calibration after cleaning?
    Date2025-12-22

    Does the Pneumatic Anchor Cable Releaser need calibration after cleaning?

    Yes, calibration is required. After cleaning, the hydraulic system of the releaser may retain impurities or the seals may have changed condition, directly affecting its pressure accuracy and reliabili
  • How to Properly Clean a Mining Pneumatic Anchor Cable Releaser?
    Date2025-12-19

    How to Properly Clean a Mining Pneumatic Anchor Cable Releaser?

    1. External Cleaning: First, disconnect all connections. Use a soft cloth or brush to remove large pieces of coal slag and grease from the surface. Stubborn oil stains can be wiped with a neutral dete
  • How to determine if anchor cable tensioning is in place?
    Date2025-12-17

    How to determine if anchor cable tensioning is in place?

    1. Check the tension stress value. This is the most direct criterion. During tensioning, the hydraulic pressure gauge reading should reach the designed tension stress value. For example, if the design
  • How to Properly Use Mining Anchor Cable Tensioning Equipment?
    Date2025-12-15

    How to Properly Use Mining Anchor Cable Tensioning Equipment?

    1. Pre-Operation Preparation Equipment Inspection: Ensure the pneumatic pump, tensioning jack, high-pressure oil pipes, etc., are securely connected and leak-free. Check that the oil pump has sufficie
First 3456789 Last 6/9

Contact Us

  • LocationNo.69, Yabao Avenue, Jiangyin City, Jiangsu Province, China
  • Phone+8613812591787
  • Eail1frank.jin@hiscore-mach.com

Quick Navigation

  • Home
  • Products
  • Videos
  • News
  • Blog
  • Contact Us
  • Showroom
  • Article
  • Sitemap

Categories

  • High-precision Gears
  • Coal Mine and Tunneling Applications
  • Mining Drilling Machinery
  • Pneumatic Component

Inquiry

Please leave your E-mail to us and contact us within 24 hours.
Inquiry now
Copyright © Hiscore Machinery Technology Co., Ltd. All Rights Reserved.